Hydrant Dispenser
Pressure Setting
- 150 psi
Flow rate and pump unit
- 1250 LPM
Design approvals
- EI 1581 5th edition / EI 1583 6th edition
- NFPA 407
Filtration
- Filter monitor - horizontal aligned with air eliminator and relief valve
Design specifications
- Piping stainless steel SS 316 Hydraulic operated lifting platform
- Three refueling pressure nozzles – one 2 ½” x 15 m on hose reel and two 2 ½” x 3 mon platform
- One 4” x 7.5 m intake hydrant hose
Sampling features
- Multiple sampling points with spring loaded ball valves - filter sump, filter inlet, tank sump and filter outlet
- One unit of in-lined sampling jar for quick sampling during refuelling
Safety features
- Deadman control
- Bonding cable for electrostatic charge
- Emergency shut down system
- Multiple points Interlocking systems
- Fire extinguishers
Options
- Extra air reservoir tank
- Additional Hose end pressure regulators